Availability: | |
---|---|
PDF Export | |
Product Overview
Pollution Level
● The CDM3 series operates in pollution class 3.
● The CDM3 series operates in a pollution class 3 environment (industrial environment) as defined by the IEC 60947-1 and 60664-1 standards.
Resistance to Heat and Humidity
● Dry cold, dry heat, humid heat
Technical Parameters
Frame Current | CDM3-63 | CDM3-100 | CDM3-125 | CDM3-160 | |||||
---|---|---|---|---|---|---|---|---|---|
Rated Voltage Ue(v) | 400/415 | 400/415/690 | 400/415/690 | 400/415/690 | |||||
Rated Insulation Voltage Ui(v) | 800 | 800 | 800 | 800 | |||||
Rated Impulse Withstand Voltage Uimp(kV) | 8 | 8 | 8 | 8 | |||||
Rated Current In(A) | 10-63 | 10-100 | 16-100 | 10-125 | 40-125 | 100-160 | |||
Number of poles Pole(3P.4P-A/B) | 3/4 | 3/4 | 3 | 3/4 | 3/4 | 3 | |||
C | F | C | F | C | L | S | F | ||
Rated Ultimate Short-Circuit Breaking Capacity lcu(kA) | 50/60HZ AC 400/415V | 25 | 50 | 25 | 50 | 25 | 35 | 35 | 50 |
50/60HZ AC 690V | / | / | / | 8 | / | 8 | 8 | 8 | |
Electrical Life | AC 400 / 415V | 8000 | 8000 | 8000 | 8000 |
Frame Current | CDM3-250 | CDM3-400 | CDM3-630 | CDM3-800 | CDM3-1250 | |
---|---|---|---|---|---|---|
Rated Voltage Ue(v) | 400/415/690 | 400/415/690 | 400/415/690 | 400/690 | 400/415 | |
Rated Insulation Voltage Ui(v) | 800 | 800 | 800 | 800 | 800 | |
Rated Impulse Withstand Voltage Uimp(kV) | 8 | 8 | 8 | 8 | 8 | |
Rated Current In(A) | 100-250 | 200-400 | 400/500/630 | 630-800 | 700-1250 | |
Number of poles Pole(3P.4P-A/B) | 3/4 | 3/4 | 3/4 | 3/4 | 3 | |
Electrical life | AC 400 / 415V | 8000 | 7500 | 7500 | 2500 | 2500 |
Product Overview
Pollution Level
● The CDM3 series operates in pollution class 3.
● The CDM3 series operates in a pollution class 3 environment (industrial environment) as defined by the IEC 60947-1 and 60664-1 standards.
Resistance to Heat and Humidity
● Dry cold, dry heat, humid heat
Technical Parameters
Frame Current | CDM3-63 | CDM3-100 | CDM3-125 | CDM3-160 | |||||
---|---|---|---|---|---|---|---|---|---|
Rated Voltage Ue(v) | 400/415 | 400/415/690 | 400/415/690 | 400/415/690 | |||||
Rated Insulation Voltage Ui(v) | 800 | 800 | 800 | 800 | |||||
Rated Impulse Withstand Voltage Uimp(kV) | 8 | 8 | 8 | 8 | |||||
Rated Current In(A) | 10-63 | 10-100 | 16-100 | 10-125 | 40-125 | 100-160 | |||
Number of poles Pole(3P.4P-A/B) | 3/4 | 3/4 | 3 | 3/4 | 3/4 | 3 | |||
C | F | C | F | C | L | S | F | ||
Rated Ultimate Short-Circuit Breaking Capacity lcu(kA) | 50/60HZ AC 400/415V | 25 | 50 | 25 | 50 | 25 | 35 | 35 | 50 |
50/60HZ AC 690V | / | / | / | 8 | / | 8 | 8 | 8 | |
Electrical Life | AC 400 / 415V | 8000 | 8000 | 8000 | 8000 |
Frame Current | CDM3-250 | CDM3-400 | CDM3-630 | CDM3-800 | CDM3-1250 | |
---|---|---|---|---|---|---|
Rated Voltage Ue(v) | 400/415/690 | 400/415/690 | 400/415/690 | 400/690 | 400/415 | |
Rated Insulation Voltage Ui(v) | 800 | 800 | 800 | 800 | 800 | |
Rated Impulse Withstand Voltage Uimp(kV) | 8 | 8 | 8 | 8 | 8 | |
Rated Current In(A) | 100-250 | 200-400 | 400/500/630 | 630-800 | 700-1250 | |
Number of poles Pole(3P.4P-A/B) | 3/4 | 3/4 | 3/4 | 3/4 | 3 | |
Electrical life | AC 400 / 415V | 8000 | 7500 | 7500 | 2500 | 2500 |